Flamefast Heat Treatment Gas Detection Systems Gas Proving System Health & Safety Project Services Used Equipment Schemes of Work Contact Us
T2 T4 Gas Air Torches

Heat Treatment

Gas/Air Torches

Developed to give a wide range of flames at the turn of a valve, ideal for brazing, soldering, metal melting, heat treatment, glass, lead and tinning work.

The Flamefast T range of Gas/Air torches are constructed from nickel plated brass with a heat resistant steel burner head ensuring long and reliable service. Two torches are available, the T4 which is designed for heavy brazing and the T2 which is smaller in size with a heat output for more delicate work. The torches are designed to work with an air supply pressure regulated at 4 lbs/in2 - 270 mbar.

CONVENIENT TO USE

Permanent pilot flame, parking hook, screwed connections for flexible hoses and work piece cooling by rapid air blast plus a choice of models for natural or bottled
gas, make the T range of gas/air torches simple and convenient to use.

ONE HANDED OPERATION

Built-in balance and position of controls enables effortless single handed operation. Instantaneous adjustment of flame size, shape and intensity over the full range
is achieved by a single rotary control valve and air throttle button.

IMPORTANT SAFETY MEASURES

  • Use only the gas pressure recommended by Flamefast.
  • Do not use propane or butane at high pressure.
  • Make sure a fixed pressure regulator is used, available from Flamefast.
  • Always have a non-return valve fitted to both gas and air lines, available from Flamefast.

AIR SUPPLY

If the air supply is delivered by an air compressor, a nonreturn valve and pressure gauge must be fitted in the air line. If the air supply is delivered by a vane compressor a nonreturn
valve is not needed in the air line.

Model Air pressure Air consumption
PSI mbar cu. ft. min.
T2 4 270 2.0
T4 4 270 6.8

Model

Air pressure

Air consumption

 

PSI

mbar

cu. ft. min.

T2

4

270

2.0

T4

4

270

6.8

 

If compressed air is not available a range of blowers and torches have been developed by Flamefast to give similar performance characteristics.

GAS CONSUMPTION

Model

Gas consumption

Heat output

 

m3/h

Kg./h

Btu/h

Kw

T2

0.55m3/h

0.41

20000

5.9

T4

2.2m3/h

1.66

80000

23.5

 

OPERATING GAS PRESSURES

Natural Gas

20 mbar

Propane

35 mbar

Butane

28 mbar

 

STANDARD EQUIPMENT

  • Permanent pilot flame.
  • Parking hook.
  • Screwed connections for flexible hoses.
  • Plastic hand grip.
  • Flame softening button.


OPTIONAL EXTRAS

  • Gas and air colour coded hoses.
  • Carton of 10 heat reflective blocks.
  • 300mm revolving brazing table.
  • Gas and air non-return valves.
  • Fume extraction equipment to meet the requirements of COSHH Regulations

Please state type of gas when ordering

According to the Health & Safety at Work Act 1974, BS 4163 and COSHH Regulations it is mandatory that all fumes must be removed at source.

Product Datasheet

T2 T4 Gas Air Torches

Approx 25kb

Download Acrobat Reader

All our data sheets can be downloaded in .PDF format.

To view them, you need Adobe® Acrobat® Reader 4.0 or later. If you do not have Adobe® Acrobat® Reader 4.0 or later versions, you can download for free...

Get Acrobat Reader


If you have any questions about downloading our datasheets, please do not hesitate to contact us at sales@flamefast.com