The CRM 700 has a motorised safety tilt system that is push-button operated. When the tilt button is pressed the unit will slowly rise from the rest position towards the pouring position. With the tilt button pressed, the unit will slowly pour the molten metal into a target mould. When the tilt button is released, the unit begins to return to the rest position. The unit can be held in one position by continuously pressing and releasing the tilt button.
Ignition is automatic and there is automatic flame control with no user interaction required. On ignition, the crucible furnace is automatically put on low heat for about 5 minutes to preheat the chamber and crucible pot before ramping up to full heat input. This helps to reduce the risk of thermal shock.
This furnace has the ability to think for itself. It can re-establish firing conditions, maintain correct gas/air ratios and shut off safely if the mains electrical power or gas is cut off. Efficient insulation and refractory materials give fast heating together with fuel gas economy.
Designed to work with natural gas, propane, or butane.
DIMENSIONS
Height 1050mm . Width 500mm . Depth 883mm
AX25 Capacity Crucible Pot Typical Melting Times from cold
Al - 4kgs 25 minutes
Cu/Zn - 11kgs 35 minutes
Performance
GAS TYPE |
RATE |
BTU/HR |
KW |
Pressure |
Natural Gas |
2.73m3/h |
100,000 |
29.3 |
20 mbar |
Propane |
2.1kg/h |
100,000 |
29.3 |
35 mbar |
Butane |
2.1kg/h |
100,000 |
29.3 |
28 mbar |
Maximum Temperature 1400 C
Electrics 110Watts . 220 - 240 Volt single phase
Weight 140 Kg
STANDARD EQUIPMENT
- Whisper quiet blower fan.
- Super efficient insulation.
- Push button, no volt release starter.
- Requires manual restart after power failure.
- Electronic flame failure protection with automatic ignition.
- Gas non-return valve.
- AX25 crucible pot.
- Operation/Instruction manual.
OPTIONAL EXTRAS
- Replacement AX25 crucible pot.
- Face shield (Polycarbonate) (22mm).
- Heat resistant gloves.
- Chrome leather leggings.
- Chrome leather apron.
- Hardware support casting kit.
- Moulding bench.
- Fume extraction to meet the requirements of COSHH Regulations.
Please state type of gas when ordering.
According to the Health & Safety at Work Act 1974, BS 4163
and COSHH Regulations it is mandatory that all fumes must be removed
at source.