Flamefast Gas Torches - T2 & T4
Two torches are available, the T4 which is designed for heavy brazing and the T2 which is smaller in size with a heat output for more delicate work.
Top Key Features
- Parking hook, & Screwed connection for flexible hoses
- Work piece cooling by rapid air blast
- A choice of models for natural or bottled gas
- Easy and convenient to use
- UK Manufactured
Overview
Two torches are available, the T4 which is designed for heavy brazing and the T2 which is smaller in size with a heat output for more delicate work. The torches are designed to work with an a compressed air supply pressure regulated at 4 PSI, 2 - 270 mbar.
The Flamefast T-range of Gas/Air torches is constructed from chrome plated brass with a heat resistant steel burner head ensuring long and reliable service. Developed to give a wide range of flames at the turn of a valve. Ideal for brazing, soldering, metal melting, heat treatment, glass, lead and tinning work.
Key Features
- Parking hook, & Screwed connection for flexible hoses
- Work piece cooling by rapid air blast
- A choice of models for natural or bottled gas
- Easy and convenient to use
- Plastic hand grip & thumb wheel for one handed adjustment
- Built in balance and position of controls enables effortless single handed operation.
- Instantaneous adjustment of flame size, shape and intensity over the full range is achieved by a single rotary control valve
- UK Manufactured
Dimensions
Weight: | T2: 0.25 kg - T4: 0.6 kg |
---|
Technical Specifications
Features: | Compressed air supply |
---|---|
Frame Material: | Plastic hand grip |
Safety: | Use only the gas pressure recommended by Flamefast Do not use propane or butane at hight pressure Make sure a fixed pressure regulator is used, available from Flamefast Always have a non-return valve fitted to both gas and air lines. (available from Flamefast) Appropriate PPE must be warn at all times when operating equipment |
Warranty: | 1 Years |
PLEASE STATE GAS TYPE WHEN ORDERING
IMPORTANT NOTICE: ACCORDING TO THE HEALTH & SAFETY AT WORK ACT 1974, BS 4163 AND COSHH REGULATIONS IT IS MANDATORY THAT ALL FUMES MUST BE REMOVED AT SOURCE.
Performance
Air Supply
- If the air supply is delivered by an air compressor, a non-return valve and pressure gauge must be fitted in the air line.
- If the air supply is delivered by a vane compressor a non-return valve is not needed in the air line.
 | AIR PRESSURE |  | AIR CONSUMPTION |
Model | PSI | MBar | CU. Ft/min |
T2 | 4 | 270 | 2.0 |
T4 | 4 | 270 | 6.8 |
Â
Performance
Gas Type | Pressure | Â | Â | Â |
Natural gas | 20 mbar | Â | Â | Â |
Propane | 35 mbar | Â | Â | Â |
Butane | 28 mbar | Â | Â | Â |
Â
Gas Consumption
Model | N.G m3/H | LPG KG/H | BTU/H | KW |
T2 | 0.55 | 0.41 | 20 000 | 5.9 |
T4 | 2.2 | 1.66 | 80 000 | 23.5 |
Â
Optional Extras
- Gas and air colour coded hoses
- Carton of 10 heat reflective blocks
- 300mm revolving brazing table
- Gas and air non-return valves
- *Fume extraction equipment that meets COSHH Regulations
*Fume extraction is mandatory as per HSG258/ COSHH regulations. Please contact us for advice and cost
Part Numbers
50TRC-A24 NG | T2 Natural Gas |
50TRC-A24 LG | T2 LPG |
50TRC-A22 NG | T4 Natural Gas |
50TRC-A22 LG | T4 LPG |